Structural stress analysis of storage tank 21.05 B003 at Lenzing Biocel Paskov company – it is reconstruction of storage tank, where vapour part of storage tank was replaced (1000 mm of shell and whole roof with nozzles). New part of storage tank from material DIN 1.4462 duplex was made.
Technomont Frýdek-Místek s.r.o., Czech Republic
2022